Dry block temperature Calibrator (TS)

Dry block temperature Calibrator (TS)

Overview:

This dry block temperature calibrator is a compact, high-performance instrument designed for accurate and efficient calibration of temperature sensing devices across industrial and laboratory environments. Engineered with advanced PID control, it delivers excellent stability, uniform temperature distribution, and rapid heating and cooling, ensuring reliable calibration results in minimal time. The lightweight, portable design with optional carrying case makes it particularly suitable for both on-site field calibration and workshop use.

With its robust construction, user-friendly operation, and dependable performance, the unit serves as an essential tool for calibration of thermocouples, RTDs and other thermal instruments where precision and convenience are critical. Its optimized immersion depth and precision-controlled heating block enable reliable calibration even for long-stem probes and industrial temperature sensors. The instrument’s fast stabilization capability reduces downtime, improving productivity in calibration laboratories and maintenance operations. Designed for durability and repeatable performance, it provides a dependable solution for professionals requiring precise, time-efficient thermal calibration across a wide range of applications. Dry block temperature Calibrator (TS) Applications:

  • Calibration and testing of thermocouples (TC) and RTD temperature sensors.
  • Verification and calibration of industrial temperature gauges and dial thermometers.
  • Testing and calibration of temperature switches and thermostats.
  • On-site and laboratory temperature calibration in process industries such as oil & gas, pharmaceuticals, power plants, and manufacturing.
  • Maintenance and quality assurance departments for periodic instrument validation.
  • Research and development laboratories requiring stable and uniform temperature sources.
Model 400 TS & 650 TS
Range 400 TS 650 TS
30 to 400°C 30 to 650°C
Resolution 0.1°C
Accuracy 400 TS 650 TS
±0.6°C ±1.0°C
Stability ±0.1°C
Stabilization Time 10 minutes
Units °C/°F Switchable
Display LED Green
Heating Time (ambient to 123°c) 400 TS 650 TS
5 Min 12 Min
Cooling Time (ambient to negative max.) 400 TS 650 TS
18 Min 28 Min
Radial Uniformity 400 TS 650 TS
±0.05°C @ 50°C to ±0.1°C @ 400°C ±0.05°C @ 50°C to ±0.1°C @ 650°C
Switch Test Facility Provided
Insertion Tube Diameter 25.4mm
Insertion Tube Depth 110mm
Power Supply 230V AC ±2.5/50 Hz
Weight 5.8 Kgs.